Difference between revisions of "Clivusmultrum M12 Composting Toilet System"
| (8 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
| + | <!-- This shows the authors that have edited a page and gives them credit for their contribution --> | ||
{{Template:CiteAuthors}} | {{Template:CiteAuthors}} | ||
| − | + | '''This system is also called:''' | |
| − | |||
| − | + | '''Keywords:''' Waterless toilet | |
| − | |||
| − | = | + | =Principles of Operation= |
| − | + | <!-- Only briefly state anything that the StemNode Diagrams can cover within subsystems. This section is often omitted for specific systems (manuals on a specific make, model, or serial number) --> | |
| − | + | Composting is assisted by worms, added 1 year after startup. Toilets are either waterless or foam based and sit directly above the composting unit. The waterless toilets connect to the composting unit directly via a 14” diameter polyethylene shoot. The foam flush toilets have a 4” hole at the bottom of the bowl with opens into the shoot. The foam flush toilets need to be “flushed” before and after each use. Ventilation occurs by drawing air down the shoot, through the composting unit, then up a vent stack. The system includes a compost tea tank and removal pump that allows for the compost tea to be stored and distributed for land applications. | |
| − | + | ==Operating Specifications== | |
| + | ===Capacity=== | ||
| + | <!-- Typically used for specific systems (ones that have a make and model) --> | ||
| + | A single unit is rated for 18,000 to 65,000 uses per year. | ||
| − | + | ===Requirements for Operation=== | |
| + | <!-- Only briefly state anything that the StemNode Diagrams can cover as inputs. Use metric base units (Kg, L, m, A, cd, mol) where practical, with the exception of temperature which should be in Celsius instead of Kelvin. Chemical and biochemical processes should be in molar ratios.--> | ||
| − | + | '''Composter''' | |
| + | Moistening system: 1 gal/day. Works on in house water supply so no additional pump is needed. Solenoid is 120 VAC, 50/60 Hz. There is no heating system. Liquid removal pump - pumps compost tea to storage. Operates ~4 min/day. - 115V AC, 5 Amp, 20.4 gpm. 62Wx105Lx58.5H inches, 132 cubic feet. Wood shavings should be amended into the compost, but these can be procured from local waste sources (cedar should not be used). | ||
| − | == Maintenance == | + | '''Toilet''' |
| − | + | Two toilet options exist; a waterless toilet or a foam flush which requires 0.2 L per flush plus a foaming agent (~185 USD/year). The foam flush requires an electrical connection. Non-potable water can be used. Fan: 115 V, 0.67 amp, 71 W, 60 Hz, 243 cfm, runs continuously. | |
| + | |||
| + | '''Compost Tea Tank''' | ||
| + | 500 gallon volume. | ||
| + | |||
| + | ===Ratios of Inputs to Outputs=== | ||
| + | <!--Use metric base units (Kg, L, m, A, cd, mol) where practical, with the exception of temperature which should be in Celsius instead of Kelvin. Chemical and biochemical processes should be in molar ratios. Alternate units can be placed in parentheses --> | ||
| + | |||
| + | |||
| + | =Maintenance and Repair= | ||
| + | |||
| + | ==Maintenance Schedule== | ||
| + | <!--This section is for expected maintenance. Repairs of unexpected problems should go under the "Typical Failures and Known Solutions" section. Cost data should be omitted since it will change over time--> | ||
| + | |||
| + | <!--This table is generally only appropriate for specific systems (manuals on a specific make and model). Consider omitting for generalized systems--> | ||
| + | |||
| + | {| class="wikitable sortable" | ||
| + | |- | ||
| + | ! Frequency | ||
| + | ! Action | ||
| + | ! Who Performs? | ||
| + | ! Time to Complete | ||
| + | ! Notes | ||
| + | |- | ||
| + | |One year after startup | ||
| + | |Add worms | ||
| + | |User/Operator | ||
| + | | - | ||
| + | | - | ||
| + | |- | ||
| + | | 2-3 months | ||
| + | | Add bulking material (e.g. pine shavings) and knock down cone/pile below the toilet, rake compost into the "toe" of the unit. | ||
| + | | User/Operator | ||
| + | | 10 minutes | ||
| + | |- | ||
| + | |- | ||
| + | |5-7 years (depending on use) | ||
| + | |Empty compost from unit | ||
| + | |User/Operator | ||
| + | | - | ||
| + | | - | ||
| + | |- | ||
| + | | ? | ||
| + | |Replace foaming agent | ||
| + | | - | ||
| + | | Only for foam flush type toilets | ||
| + | |} | ||
| + | |||
| + | ==Known Failures and Solutions== | ||
| + | <!--Historical significance of a failure is better suited for Wikipedia or other sites. You are encouraged to link out to these sites from this section. --> | ||
| + | |||
| + | <!--Problems are user oriented since a problem to one entity may not be a problem to another, Symptoms are an observable, and sometimes measurable trait, Fundamental causes connect the problem with subsystems or symptoms, and Solutions are actions that can be taken to remedy the problem --> | ||
| + | |||
| + | {| class="wikitable sortable" | ||
| + | |- | ||
| + | ! Problem | ||
| + | ! Symptom (s) | ||
| + | ! Fundamental Cause | ||
| + | ! Solution | ||
| + | |||
| + | |- | ||
| + | |Failure of refuse to break down | ||
| + | |Increased accumulation of material in the composter | ||
| + | |Bulking agents need to be high in carbon, low in nutrients, and rapidly degradable. Naturaly resistant bulking agents (e.g. Cedar) should not be used. Further, adequate air flow is needed to ensure break down. | ||
| + | |Check bulking agents and change if needed. Check ventilation system for blockages. | ||
| + | |} | ||
| + | |||
| + | ==Warranties== | ||
| + | <!--This only applies to specific systems (manuals on a specific make, model, or serial number). Delete section for generalized systems --> | ||
| + | |||
| + | =System Variations= | ||
| + | <!--Discuss Variations or modification on the System --> | ||
| + | |||
| + | Foam flush vs. Non flush varieties of toilets exist. | ||
| + | |||
| + | ==Instances of the System== | ||
| + | <!--This only applies to generalized systems (those that do not have a make, model, or serial number) that have specific systems within them. Delete section for specific systems --> | ||
| + | |||
| + | {| class="wikitable sortable" | ||
| + | |- | ||
| + | ! Location | ||
| + | ! Date Installed | ||
| + | ! Owner/Operator | ||
| + | |- | ||
| + | | | ||
| + | | | ||
| + | | | ||
| + | |} | ||
| + | |||
| + | ==Versions of the System== | ||
| + | <!--This only applies to specialized systems (those that have a make, model that have specific systems within them. Delete section for specific systems --> | ||
| + | |||
| + | {| class="wikitable sortable" | ||
| + | |- | ||
| + | ! Version | ||
| + | ! Dates of Production | ||
| + | ! End of Production | ||
| + | ! Number Produced | ||
| + | |||
| + | |- | ||
| + | | (Insert Version) | ||
| + | | (State a Date) | ||
| + | | (State a Date) | ||
| + | | (State a unitless quantity) | ||
| + | |} | ||
| + | |||
| + | =Safety= | ||
| + | <!--Personal protective equipment, or operating requirements --> | ||
| + | |||
| + | =Cultural Significance= | ||
| + | <!--An opportunity to give credit to entire cultures when an individual cannot be credited, and/or relay ethnological significance --> | ||
| + | |||
| + | =Intellectual Property= | ||
| + | <!-- List any relevant patents, copyrights, or trade secrets on the system --> | ||
| + | |||
| + | =Regulations= | ||
| + | <!-- Subsections should be organized in alphabetical order by country, then state, where the regulations apply --> | ||
| + | |||
| + | =Cost Data= | ||
| + | Estimated Equipment Price for system: $10,000 for a system with two waterless toilets, or $15,000 for a system with two foam flush toilets. Individually sold, the waterless toilets are $425 per fixture and the foam flush toilets are $2700 per fixture. For the waterless fixture there are no consumables. For the foam flush, $185 per year should be budgeted for the foam producing soap. For either type, wood shavings should be amended into the compost, but these can be procured from local waste sources. | ||
| + | |||
| + | =Manufacturer Information= | ||
| + | Clivus Malturm, [[clivusmultrum.com]], 800.425.4887, Lawrence, MA | ||
Latest revision as of 10:47, 9 November 2018
Authors:
This system is also called:
Keywords: Waterless toilet
Contents
Principles of Operation
Composting is assisted by worms, added 1 year after startup. Toilets are either waterless or foam based and sit directly above the composting unit. The waterless toilets connect to the composting unit directly via a 14” diameter polyethylene shoot. The foam flush toilets have a 4” hole at the bottom of the bowl with opens into the shoot. The foam flush toilets need to be “flushed” before and after each use. Ventilation occurs by drawing air down the shoot, through the composting unit, then up a vent stack. The system includes a compost tea tank and removal pump that allows for the compost tea to be stored and distributed for land applications.
Operating Specifications
Capacity
A single unit is rated for 18,000 to 65,000 uses per year.
Requirements for Operation
Composter Moistening system: 1 gal/day. Works on in house water supply so no additional pump is needed. Solenoid is 120 VAC, 50/60 Hz. There is no heating system. Liquid removal pump - pumps compost tea to storage. Operates ~4 min/day. - 115V AC, 5 Amp, 20.4 gpm. 62Wx105Lx58.5H inches, 132 cubic feet. Wood shavings should be amended into the compost, but these can be procured from local waste sources (cedar should not be used).
Toilet Two toilet options exist; a waterless toilet or a foam flush which requires 0.2 L per flush plus a foaming agent (~185 USD/year). The foam flush requires an electrical connection. Non-potable water can be used. Fan: 115 V, 0.67 amp, 71 W, 60 Hz, 243 cfm, runs continuously.
Compost Tea Tank 500 gallon volume.
Ratios of Inputs to Outputs
Maintenance and Repair
Maintenance Schedule
| Frequency | Action | Who Performs? | Time to Complete | Notes |
|---|---|---|---|---|
| One year after startup | Add worms | User/Operator | - | - |
| 2-3 months | Add bulking material (e.g. pine shavings) and knock down cone/pile below the toilet, rake compost into the "toe" of the unit. | User/Operator | 10 minutes | |
| 5-7 years (depending on use) | Empty compost from unit | User/Operator | - | - |
| ? | Replace foaming agent | - | Only for foam flush type toilets |
Known Failures and Solutions
| Problem | Symptom (s) | Fundamental Cause | Solution |
|---|---|---|---|
| Failure of refuse to break down | Increased accumulation of material in the composter | Bulking agents need to be high in carbon, low in nutrients, and rapidly degradable. Naturaly resistant bulking agents (e.g. Cedar) should not be used. Further, adequate air flow is needed to ensure break down. | Check bulking agents and change if needed. Check ventilation system for blockages. |
Warranties
System Variations
Foam flush vs. Non flush varieties of toilets exist.
Instances of the System
| Location | Date Installed | Owner/Operator |
|---|---|---|
Versions of the System
| Version | Dates of Production | End of Production | Number Produced |
|---|---|---|---|
| (Insert Version) | (State a Date) | (State a Date) | (State a unitless quantity) |
Safety
Cultural Significance
Intellectual Property
Regulations
Cost Data
Estimated Equipment Price for system: $10,000 for a system with two waterless toilets, or $15,000 for a system with two foam flush toilets. Individually sold, the waterless toilets are $425 per fixture and the foam flush toilets are $2700 per fixture. For the waterless fixture there are no consumables. For the foam flush, $185 per year should be budgeted for the foam producing soap. For either type, wood shavings should be amended into the compost, but these can be procured from local waste sources.
Manufacturer Information
Clivus Malturm, clivusmultrum.com, 800.425.4887, Lawrence, MA